HC7 miniBOOSTER

HC7 versions: 5 different intensification factors

PIN: 20 – 207 bar (inlet pressure)

PH: 2000 bar maximum (outlet pressure)

PRETURN: As low as possible (return pressure to tank)

POUTLET: PH = (PIN – PReturn) x i (intensification)

Mounting: Inline tube

Accessories: Pilot-operated dump valve incorporated

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled

 

 

Description

The HC7 is a very compact high-pressure unit capable of delivering pressure up to 2,000 bar weighing only 1.5 kg. It is ideal for use in portable applications like on power packs.

The HC7 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. With the choice of different high- pressure adapters, a variety of threads can be obtained from the M22x1.5 thread in the HP port. Higher pressure is available on request.

Flow rates

Intensification factor
i

Max. outlet flow
l/min

Max. inlet flow
l/min

5.0

1.6

14.0

6.6

1.3

13.0

9.0

0.9

13.0

13.0

0.6

12.0

20.0

0.3

12.0

Functions

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high-pressure side H. In this condition maximum flow through the booster is achieved, giving a fast-forward function.

When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on the high-pressure side H is reached. If a pressure drop on the high-pressure side exists due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

Function diagram

 Function diagram 7-105-00 

Connection types

Connection

IN / R

1

1/4" BSPP

2

7/16-20" UNF

 

Max. tightening torque BSPP

IN / R

1/4" BSPP

  with steel washer

4.0 da/Nm

  with aluminium washer

3.0 da/Nm

  with cutting edge

4.0 da/Nm

 

Max. tightening torque UNF

IN / R

7/16-20" UNF

  with o-ring

2.0 da/Nm

 

High-pressure adapters

  Ordering code

Male connection 1

Connection 2

Max. pressure

7-432

M22 x 1.5

9/16-18 UNF

2,600 bar

7-433

M22 x 1.5

1/4" BSPP

2,600 bar

7-434

M22 x 1.5

Plug

2,600 bar

7-435

M22 x 1.5

1/4" BSPP

   800 bar

7-439

M22 x 1.5

9/16-18 UNF

1,380 bar

7-445

M22 x 1.5

1/4" BSPP male

2,600 bar

7-446

M22 x 1.5

M22 x 1.5

2,600 bar

7-447

M22 x 1.5

7/16-20 UNF

1,380 bar

High-pressure adapter ordering codes and specifications can be seen from the table in the PDF-file below:

 High-pressure adapters: 7-900-05

Fluids and materials

Please see: General specifications

Ordering an HC7

Ordering example of an HC7 with i = 13.0, H1 M22 x 1.5 and H2 9/16-18 UNF,

DV incorporated and BSPP connections: HC7 - 13.0 - B - 12

Please note!

High-pressure adapter ordering code – see table

Model

Intensification, i

Dump valve

Connections

HC7


your selection...


your selection...


see table below

see flow rate table

A = (no) / A model

B = (yes) / B model

G = (proportional) / G model

  Ordering code

IN, R

H1

H2

H3

  HC7-___-__-11

1/4" BSPP

M22 x 1.5

  HC7-___-__-21

7/16-20 UNF

M22 x 1.5

  HC7-___-__-12

1/4" BSPP

M22 x 1.5

9/16-18 UNF

  HC7-___-__-22

7/16-20 UNF

M22 x 1.5

9/16-18 UNF

  HC7-___-__-13

1/4" BSPP

M22 x 1.5

9/16-18 UNF

9/16-18 UNF

  HC7-___-__-23

7/16-20 UNF

M22 x 1.5

9/16-18 UNF

9/16-18 UNF

 