miniBOOSTER logotype Photo: HC1 hydraulic intensifier. Minimum Size – Maximum Power

miniBOOSTER Hydraulics A/S
Ellegårdvej 25G
DK - 6400 Sønderborg
Tel:  +45 7442 9292
Fax: +45 7442 4204

Print Icon Print friendly version

The HC3 - C miniBOOSTER


Photo: HC3 - C miniBOOSTER

HC3 versions: 11 different intensification factors

PIN: 20 – 200 bar (inlet pressure)

PH: 500 bar maximum (outlet pressure)

PRETURN: As low as possible (Return pressure to tank)

Intensification ratios: PH = (PIN – PReturn) i (Intensification)

Mounting: NG6 (D03) stacking manifold system

Accessories: Pilot operated dump valve available

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled



Image-link: Back to top of page.  Description of the HC3 - C miniBOOSTER hydraulic intensifier

The HC3 – C, a variant of the HC3, for applications with larger flow rates, providing a fast response with build in by-pass up to 50 l/min. It is a compact unit weighing only 4.0 kg, designed for use in NG6 (D03) stacking manifold systems. Maximum outlet pressure is 350 bar in standard versions. An adjustment of the outlet pressure is carried out by varying the supplied pressure.



Image-link: Back to top of page.  Flow Rates

Intensification factor
i
Max. outlet flow
l/min
Max. inlet flow
l/min
1.2 1.2 8.0
1.5 1.0 8.0
2.0 2.0 12.0
2.8 2.2 13.0
3.2 2.5 15.0
4.0 2.0 14.0
5.0 1.6 14.0
6.6 1.3 13.0
9.0 0.9 13.0
13.0 0.6 12.0
20.0 0.3 12.0



Image-link: Back to top of page.  Dimensions


Drawing: HC3 - C miniBOOSTER dimensions.



Image-link: Back to top of page.  Functions

When pump pressure is reached on the A port, check valve (b) will close and the oil will flow via the Orifice (a) to the oscillating pump unit OP. The end pressure will be achieved by the oscillating pump OP. The unit will automatically stall when end pressure on high-pressure side is reached. If there is a pressure drop on the high- pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

Function Diagram

Illustration: HC3 - C function diagram.




Image-link: Back to top of page.  Fluids and materials

Please see General Specifications.




Image-link: Back to top of page.  Ordering a HC3 - C

Ordering example of a HC3 - C with i = 4.0,
DV incorporated: HC3 - 4.0 - B - C

Model Intensification, i Dump Valve Model
HC3
 your selection...
 your selection...
C
see flow rate table A = (no) / A model
B = (yes) / B model
 G = (proportional) / G model  

BVQI ISO 9001 logo.