| Intensification factor i |
Max. outlet flow l/min |
Max. inlet flow l/min |
| 1.2 | 1.2 | 8.0 |
| 1.5 | 1.0 | 8.0 |
| 2.0 | 2.0 | 12.0 |
| 2.8 | 2.2 | 13.0 |
| 3.2 | 2.5 | 15.0 |
| 4.0 | 2.0 | 14.0 |
| 5.0 | 1.6 | 14.0 |
| 6.6 | 1.3 | 13.0 |
| 9.0 | 0.9 | 13.0 |
| 13.0 | 0.6 | 12.0 |
| 20.0 | 0.3 | 12.0 |

When pump pressure is reached on the A port, check valve (b) will close and the oil will flow via the Orifice (a) to the oscillating pump unit OP. The end pressure will be achieved by the oscillating pump OP. The unit will automatically stall when end pressure on high-pressure side is reached. If there is a pressure drop on the high- pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.
Function Diagram

Please see General Specifications.
Ordering example of a HC3 - C with i = 4.0,
DV incorporated: HC3 - 4.0 - B - C
| Model | Intensification, i | Dump Valve | Model | |||
| HC3 |
|
your selection... |
|
your selection... |
|
C |
| see flow rate table | A = (no) / A model | |||||
| B = (yes) / B model | ||||||
| G = (proportional) / G model | ||||||