miniBOOSTER logotype Photo: HC1 hydraulic intensifier. Minimum Size – Maximum Power
miniBOOSTER Hydraulics A/S
Ellegårdvej 25G
DK - 6400 Sønderborg
Tel:  +45 7442 9292
Fax: +45 7442 4204

Print Icon Print friendly version

  1. Description
  2. Flow rates
  3. Dimensions
  4. Functions
  5. Fluids and materials
  6. Ordering

The HC3 - F miniBOOSTER


Photo: HC3 - F miniBOOSTER

HC3 - F versions: 11 different intensification factors

PIN: 20 – 200 bar (inlet pressure)

PH: 500 bar maximum (outlet pressure)

PRETURN: As low as possible (Return pressure to tank)

Intensification ratios: PH = (PIN – PReturn) i (Intensification)

Mounting: Manifold system miniBOOSTER pattern

Accessories: Pilot operated dump valve available

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled



Image-link: Back to top of page.  Description

The HC3 - F is an up-right standing variant of the HC3 with a 10 micron filter and 2 orifices incorporated. It has all ports in one end and the hole pattern is a miniBOOSTER design. It is a compact unit weighing only 4.3 kg. The HC3 has the pilot operated dump valve incorporated as a standard feature. Maximum outlet pressure is 500 bar in standard versions. Adjustments of the outlet pressure is carried out by varying the supplied pressure.



Image-link: Back to top of page.  Flow Rates

Intensification factor
i
Max. outlet flow
l/min
Max. inlet flow
l/min
1.2 1.2 8.0
1.5 1.0 8.0
2.0 0.8 8.0
2.8 0.6 8.0
3.2 2.5 15.0
4.0 2.0 14.0
5.0 1.6 14.0
6.6 1.3 13.0
9.0 0.9 13.0
13.0 0.6 12.0
20.0 0.3 12.0



Image-link: Back to top of page.  Dimensions


Drawing: HC3 - F miniBOOSTER dimensions.



Image-link: Back to top of page.  Functions

The basic operation is illustrated in the function diagram. The oil is fed through the connecting plate and the filter to the IN port of the HC3 flowing freely through check valves KV1, KV2 and DV to the high- pressure side H.

From the high-pressure side H oil is fed to port A on the connecting plate. In this condition maximum flow through the booster is achieved giving a fast forward function. When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on high-pressure side is reached. If there is a pressure drop on the high- pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

Function Diagram

Illustration: HC3 - F function diagram.




Image-link: Back to top of page.  Fluids and materials

Please see General Specifications.




Image-link: Back to top of page.  Ordering a HC3 - F

Ordering example of a HC3 - F with i = 4.0,
DV incorporated: HC3 - 4.0 - B - F

Model Intensification, i Dump Valve Model
HC3
 your selection...
 your selection...
F
see flow rate table A = (no) / A model
B = (yes) / B model
 G = (proportional) / G model  

BVQI ISO 9001 logo.