Intensification factor
i |
Max. outlet flow
l/min |
Max. inlet flow
l/min |
|
1.3
|
3.1
|
50.0
|
| 1.5 | 2.5 | 50.0 |
| 1.9 | 2.0 | 50.0 |
| 2.4 | 1.5 | 50.0 |
| 3.3 | 11.0 | 70.0 |
| 4.0 | 9.0 | 70.0 |
| 4.9 | 7.0 | 70.0 |
| 6.3 | 5.5 | 70.0 |
| 8.2 | 4.5 | 70.0 |

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high pressure side H. In this condition maximum flow through the booster is achieved giving a fast forward function.
When pump pressure is reached on the high pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on high pressure side H is reached. If there is a pressure drop on the high pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.
Function Diagram

| Connection | IN / R | H |
| 1 | 1/2" BSP | 1/2" BSP |
| 2 | 3/4-16" UNF | 3/4-16" UNF |
| IN / R | H | |
| 1/2" BSP | 1/2" BSP | |
| with steel washer | 13.0 da/Nm | 13.0 da/Nm |
| with aluminium washer | 7.0 da/Nm | |
| with cutting edge | 13.0 da/Nm | 13.0 da/Nm |
| IN / R | H | |
| 3/4-16" UNF | 3/4-16" UNF | |
| with o-ring | 3.5 da/Nm | 6.0 da/Nm |
Please see General Specifications.
Ordering example of a HC6 with i = 4.0,
DV incorporated and BSP connections: HC6 - 4.0 - B - 1
| Model | Intensification, i | Dump Valve | Connections | |||
| HC6 |
|
your selection... |
|
your selection... |
|
your selection... |
| see flow rate table | A = (no) / A model | 1 | ||||
| B = (yes) / B model | 2 | |||||
| G = (proportional) / G model | ||||||