miniBOOSTER logotype Photo: HC1 hydraulic intensifier. Minimum Size – Maximum Power
miniBOOSTER Hydraulics A/S
Ellegårdvej 25G
DK - 6400 Sønderborg
Tel:  +45 7442 9292
Fax: +45 7442 4204

Print Icon Print friendly version

  1. Description
  2. Flow rates
  3. Dimensions
  4. Functions
  5. Connection types
  6. Max tightening torque BSP
  7. Max tightening torque UNF
  8. High pressure adapters
  9. Fluids and materials
  10. Ordering number

The HC7 miniBOOSTER


Photo: HC7 miniBOOSTER

HC7 versions: 5 different intensification factors

PIN: 20 – 200 bar (inlet pressure)

PH: 2000 bar maximum (outlet pressure)

PRETURN: As low as possible (Return pressure to tank)

Intensification ratios: PH = (PIN – PReturn) i (Intensification)

Mounting: Inline tube

Accessories: Pilot operated dump valve incorporated

A model = no dump valve
B model = with dump valve
G model = direct proportionally controlled



Image-link: Back to top of page.  Description

The HC7 is a very compact high pressure unit capable of delivering pressure up to 2000 bar with an weight of only 1.5 kg. It is ideal for use in portable applications like on power packs. The HC7 raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure. Adjustment of the outlet pressure is carried out by varying the supplied pressure. With the choice of different high pressure adapters a variety of threads can be obtained from the M22x1.5 thread in the HP port.



Image-link: Back to top of page.  Flow Rates

Intensification factor
i
Max. outlet flow
l/min
Max. inlet flow
l/min
5.0
1.6
14.0
6.6 1.3 13.0
9.0 0.9 13.0
13.0 0.6 12.0
20.0 0.3 12.0



Image-link: Back to top of page.  Dimensions


Drawing: HC7 miniBOOSTER dimensions.



Image-link: Back to top of page.  Functions

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves KV1, KV2 and DV to the high pressure side H. In this condition maximum flow through the booster is achieved giving a fast forward function.

When pump pressure is reached on the high pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump unit OP. The unit will automatically stall when end pressure on high pressure side H is reached. If there is a pressure drop on the high pressure side due to consumption or leakage, the OP valve will automatically operate to maintain the end pressure.

Function Diagram

Illustration: HC7 function diagram.




Image-link: Back to top of page.  Connection types

Connection IN / R
1 1/4" BSP
2 7/16-20" UNF




Image-link: Back to top of page.  Max. tightening torque BSP

IN / R
1/4" BSP
  with steel washer 4.0 da/Nm
  with aluminium washer 3.0 da/Nm
  with cutting edge 4.0 da/Nm




Image-link: Back to top of page.  Max. tightening torque UNF

IN / R
7/16-20" UNF
  with o-ring 2.0 da/Nm




Image-link: Back to top of page.  High pressure adapters

  Ordering Code Male connection 1 Female connection 2
  7-432 M22 x 1.5 9/16-18 UNF
  7-433 M22 x 1.5 1/4" BSP
  7-434 M22 x 1.5 Plug




Image-link: Back to top of page.  Fluids and materials

Please see General Specifications.




Image-link: Back to top of page.  Ordering a HC7

Ordering example of a HC7 with i = 13.0, H1 M22 x 1.5 and H2 19/16-18 UNF.
DV incorporated and BSP connections: HC7 - 13.0 - B - 12

Model Intensification, i Dump Valve Connections
HC7
 your selection...
 your selection...
see table below
see flow rate table A = (no) / A model
B = (yes) / B model
 G = (proportional) / G model  


  Ordering Code IN, R H1 H2 H3
  HC7-___·__-11 1/4" BSP M22 x 1.5
  HC7-___·__-21 7/16-20 UNF M22 x 1.5
  HC7-___·__-12 1/4" BSP M22 x 1.5 9/16-18 UNF
  HC7-___·__-22 7/16-20 UNF M22 x 1.5 9/16-18 UNF
  HC7-___·__-13 1/4" BSP M22 x 1.5 9/16-18 UNF 9/16-18 UNF
  HC7-___·__-23 7/16-20 UNF M22 x 1.5 9/16-18 UNF 9/16-18 UNF