miniBOOSTER logotype Photo: HC1 hydraulic intensifier. Minimum Size – Maximum Power
miniBOOSTER Hydraulics A/S
Ellegårdvej 25G
DK - 6400 Sønderborg
Tel:  +45 7442 9292
Fax: +45 7442 4204

Print Icon Print friendly version

  1. Description
  2. Dimensions
  3. Functions
  4. Electrical operated
  5. Manual operated
  6. Ordering

Valve Housing CV1


Photo: Valve House CV1.

The miniBOOSTER Valve Housing is used for mounting various accessory components directly to the miniBOOSTER.

This saves space and reduces the cost of using stand alone components for these functions.

The valve housing and components selected will be factory mounted, tested and sized based on the model of miniBOOSTER selected. Housing material, aluminum.



Image-link: Back to top of page.  Description

The CV1 is a cartridge style directional valve which can be directly mounted to the miniBOOSTER. It is made for use with cartridges conforming to the C-10-4 standard. Both manual operated and solenoid operated valves are available.



Image-link: Back to top of page.  Dimensions (Valve Housing CV1 for HC2 & HC7)


Drawing: Valve House CV1 dimensions.


Image-link: Back to top of page.  Dimensions (Valve Housing CV1 for HC4)


Drawing: Valve House CV1 dimensions.


Image-link: Back to top of page.  Dimensions (Valve Housing CV1 for HC8)


Drawing: Valve House CV1 dimensions.




Image-link: Back to top of page.  Functions

Function Diagram – please see:

Manual Operated Valves
or
Electronically Operated Valves


Function Diagram: Valve Housing CV1

Image-link: Back to top of page.  Ordering a Valve Housing CV1 for HC2

Example of ordering a complete unit:
1 off Valve housing HC2 – CV1 – 1
1 off 4/3 Manual Cartridge valve CP640-1B0033D, cavity: C10-4
1 off miniBOOSTER HC2 – 4.0 – B – 1

Model Valve House Connections
 your selection...
CV1
 your selection...
For HC2, HC7 and HC8 1 = 1/4" BSP
2 = 7/16 - 20 UNF
HC4 1 = 3/8" BSP
2 = 9/16 - 18 UNF

BVQI ISO 9001 logo.