HC2DW

Data:

 

HC2DW versions: 13 different intensification factors

PIN: 20-207 bar

PH: 800 bar maximum 

PRETURN: As low as possible (return pressure to tank)

POUTLET: PH = (PIN – PRETURN) x intensification factor

Mounting: Inline tube

Weight: 8.0 kg.

Model versions:

A model = no dump valve
B model = with dump valve

Material certificate 3.1 on request

Description

The HC2DW is a dual-acting miniBOOSTER stainless steel 316L unit which is capable of delivering up to 11.0 l/min flow on the high-pressure end. Like other miniBOOSTER models, the HC2DW raises supplied pressure to a higher outlet pressure and automatically compensates for consumption of oil to maintain the high pressure.

Adjustment of the outlet pressure is carried out by varying the supplied pressure. Relative to its flow capability, the HC2DW is a compact unit weighing 8.0 kg.

Flow rates

Intensification factor
i
Max. intensified outlet flow
l/min
Max. inlet flow
l/min
1.211.015.0
1.410.615.0
1.610.215.0
1.98.815.0
2.27.815.0
2.67.015.0
3.26.215.0
4.05.014.0
5.04.014.0
6.63.213.0
9.02.213.0
13.01.512.0
20.00.712.0

Functions

The basic operation is illustrated in the function diagram. Oil is fed through the directional valve CV to the IN port, flowing freely through the check valves 2x KV1, 2x KV2 and DV to the high-pressure side H. In this condition maximum flow trough the booster is achieved giving a fast-forward function.

When pump pressure is reached on the high-pressure side H, valves KV1, KV2 and DV will close. The end pressure will be achieved by the oscillating pump units OP1 and OP2 by turns. The unit will automatically stall when end pressure on high-pressure side H is reached. If a pressure drop on the high-pressure side due to consumption or leakage, the OP1 and OP2 units will automatically operate to maintain the end pressure. It is possible to change the high-pressure connection H to the opposite end of the booster.

Function diagram

2DW-105-02

Dimensions

Dimension drawing 2DW-120-05

Connection types

ConnectionIN / RH1 / H2I1 / I2
11/4" BSPPM22 x 1.51/8" BSPP

High-pressure adapters

High-pressure adapter ordering codes and specifications are shown in the PDF-file: 7W-900-08

Dynamic seals

CodeSeal materialOutlet pressure
HHH-PUR / H-PURMax 800 bar HP
EEEPDM / EPDMMax 500 bar HP

Fluids and materials

Additional information is available on the website under Products → General specifications.

Ordering an HC2DW

Ordering example of an HC2DW with i = 4.0, DV incorporated, BSPP connections and H-PUR dynamic seals:

HC2DW – 4.0 – B – 1HH for media < 5 cSt (mm2/s) tested in water
HC2DW – 4.0 – B – 1SHH for media > 5 cSt (mm2/s) tested in hydraulic oil

Attention notes!
High-pressure adapter is required, please specify ordering code – see high-pressure adapter table.
High-pressure adapters will be factory mounted.

R

Model

  • HC2DW
R

Intensification, i

  • Select factor
  • See flow rate table
R

Model version

  • Select type
  • A = without DV
  • B = with DV
R

Connections

  • Select thread
  • 1   = BSPP, media < 5 cSt
  • 1S = BSPP, media > 5 cSt
R

Dynamic seals

  • Select seal type
  • See dynamic seal table

Max. tightening torque BSPP

IN / RI1 / I2
1/4" BSPP1/8" BSPP
with stainless steel washer4.0 da/Nm2.0 da/Nm